CASE
Home  > CASE  > 

case - 2

case - 2


undefined                

Improved top

undefined                

Improved top

undefined                

Original inside

undefined                

Improved inside

undefined                

Original top

Our suggest solution:


● Add 4pcs 3mm reinforcing ribs on the top (No#1,2), 6pcs 2.5x3mm reinforcing ribs and 2pcs reinforcing rings at the bottom inside (No#3)
● Change the 1.5x45 degree chamfer to radius 3

Customer decision:


● Considering the costs, customer accept
● Add 3 reinforcing ribs on the top, and 1 pc reinforcing ring
● Change the 1.5x45 degree chamfer to radius 3


undefined
undefined
undefined 
Original structure from Customer:


● Wall thickness only 2.4mm  with out any ribs ,which is unable to sustain the heavy weight
● Redius is too small to cause easily broken

Communication problem:


● Provided Suggestion & rejected by Client because of increased costing
● Received complain about safe risk from Consumer after shipments


undefined                

Improved sample bottom

undefined                

Improved sample top

undefined                

Testing

undefined                

Finished product

Problem solving:


● Good result of heat dissipation capability
● Resolved the safety risk problem
● Strengthen loading weight capacity  
● Improved the product quality  

Testing result:


● Can sustain 100kg weight
● Wag from side to side for 15days
● 360 days without broken


Project Case Summary